77 research outputs found

    Rapid phase-contrast magnetic resonance imaging using spiral trajectories and parallel imaging

    Get PDF
    Phase contrast (PC) MRI is a proven method of measuring blood flow in the clinical environment. Traditionally, PCMR data is acquired using cardiac gated Cartesian sequences. However, these sequences are time consuming and difficult to perform in patients with irregular heart rates. The work of my thesis covers three alternative PC sequences, all using undersampled spiral sequences with SENSE reconstruction algorithms. The first piece of work investigates real-time spiral PCMR. The spiral flow sequence was validated at rest by comparing stroke volumes in the aorta of healthy volunteers, against a retrospectively gated Cartesian sequence. By combining flow data with simultaneous blood pressure measurements during exercise, this sequence was used to quantify the hemodynamic response to physical stress. The second piece of work investigates improvements in spatial or temporal resolution for real-time PCMR, by splitting the acquisition of flow-compensated and flow-encoded data into separate short blocks. The data is then retrospectively matched in cardio-respiratory space, to remove background phase offsets. This sequence was validated (at rest) in an adult population. The improved spatial resolution was shown to provide more accurate flow measurements than standard real-time flow measurements, in a paediatric population. The third piece of work investigates prospectively triggered spiral PCMR to achieve high spatio-temporal resolution, within a short breath-hold. Flow volumes, regurgitation fraction and shunt ratios were compared from a high spatial-resolution, free breathing retrospectively gated Cartesian sequence with 3 averages (~2.5 minute scan time), a low spatial-resolution breath-hold retrospectively gated Cartesian sequence (~20 second scan time), and the (high spatial-resolution) prospectively triggered spiral sequence (~6 second scan time). It was shown that accurate flow measurements can be made in the aorta, pulmonary artery and pulmonary branches, within manageable breath-hold times for children and sick adults. This sequence may improve patient compliance and increase patient throughput

    Real-time Assessment of Right and Left Ventricular Volumes and Function in Children Using High Spatiotemporal Resolution Spiral bSSFP with Compressed Sensing

    Get PDF
    Background: Real-time (RT) assessment of ventricular volumes and function enables data acquisition during free-breathing. However, in children the requirement for high spatiotemporal resolution requires accelerated imaging techniques. In this study, we implemented a novel RT bSSFP spiral sequence reconstructed using Compressed Sensing (CS) and validated it against the breath-hold (BH) reference standard for assessment of ventricular volumes in children with heart disease. Methods: Data was acquired in 60 children. Qualitative image scoring and evaluation of ventricular volumes was performed by 3 clinical cardiac MR specialists. 30 cases were reassessed for intra-observer variability, and the other 30 cases for inter-observer variability. Results: Spiral RT images were of good quality, however qualitative scores reflected more residual artefact than standard BH images and slightly lower edge definition. Quantification of Left Ventricular (LV) and Right Ventricular (RV) metrics showed excellent correlation between the techniques with narrow limits of agreement. However, we observed small but statistically significant overestimation of LV end-diastolic volume, underestimation of LV end-systolic volume, as well as a small overestimation of RV stroke volume and ejection fraction using the RT imaging technique. No difference in inter-observer or intra-observer variability were observed between the BH and RT sequences. Conclusions: Real-time bSSFP imaging using spiral trajectories combined with a compressed sensing reconstruction is feasible. The main benefit is that it can be acquired during free breathing. However, another important secondary benefit is that a whole ventricular stack can be acquired in ~20 seconds, as opposed to ~6 minutes for standard BH imaging. Thus, this technique holds the potential to significantly shorten MR scan times in children

    The aorta after coarctation repair : effects of calibre and curvature on arterial haemodynamics (vol 21, 22, 2019)

    Get PDF
    In the original version of this article [1], published on 11 April 2019, there is 1 error in the Conclusion' paragraph of the abstract

    Abnormal wave reflections and left ventricular hypertrophy late after coarctation of the aorta repair

    Get PDF
    Patients with repaired coarctation of the aorta are thought to have increased afterload due to abnormalities in vessel structure and function. We have developed a novel cardiovascular magnetic resonance protocol that allows assessment of central hemodynamics, including central aortic systolic blood pressure, resistance, total arterial compliance, pulse wave velocity, and wave reflections. The main study aims were to (1) characterize group differences in central aortic systolic blood pressure and peripheral systolic blood pressure, (2) comprehensively evaluate afterload (including wave reflections) in the 2 groups, and (3) identify possible biomarkers among covariates associated with elevated left ventricular mass (LVM). Fifty adult patients with repaired coarctation and 25 age- and sex-matched controls were recruited. Ascending aorta area and flow waveforms were obtained using a high temporal-resolution spiral phase-contrast cardiovascular magnetic resonance flow sequence. These data were used to derive central hemodynamics and to perform wave intensity analysis noninvasively. Covariates associated with LVM were assessed using multivariable linear regression analysis. There were no significant group differences (P≥0.1) in brachial systolic, mean, or diastolic BP. However central aortic systolic blood pressure was significantly higher in patients compared with controls (113 versus 107 mm Hg, P=0.002). Patients had reduced total arterial compliance, increased pulse wave velocity, and larger backward compression waves compared with controls. LVM index was significantly higher in patients than controls (72 versus 59 g/m(2), P<0.0005). The magnitude of the backward compression waves was independently associated with variation in LVM (P=0.01). Using a novel, noninvasive hemodynamic assessment, we have shown abnormal conduit vessel function after coarctation of the aorta repair, including abnormal wave reflections that are associated with elevated LVM

    Real-time Cardiovascular MR with Spatio-temporal Artifact Suppression using Deep Learning - Proof of Concept in Congenital Heart Disease

    Get PDF
    PURPOSE: Real-time assessment of ventricular volumes requires high acceleration factors. Residual convolutional neural networks (CNN) have shown potential for removing artifacts caused by data undersampling. In this study we investigated the effect of different radial sampling patterns on the accuracy of a CNN. We also acquired actual real-time undersampled radial data in patients with congenital heart disease (CHD), and compare CNN reconstruction to Compressed Sensing (CS). METHODS: A 3D (2D plus time) CNN architecture was developed, and trained using 2276 gold-standard paired 3D data sets, with 14x radial undersampling. Four sampling schemes were tested, using 169 previously unseen 3D 'synthetic' test data sets. Actual real-time tiny Golden Angle (tGA) radial SSFP data was acquired in 10 new patients (122 3D data sets), and reconstructed using the 3D CNN as well as a CS algorithm; GRASP. RESULTS: Sampling pattern was shown to be important for image quality, and accurate visualisation of cardiac structures. For actual real-time data, overall reconstruction time with CNN (including creation of aliased images) was shown to be more than 5x faster than GRASP. Additionally, CNN image quality and accuracy of biventricular volumes was observed to be superior to GRASP for the same raw data. CONCLUSION: This paper has demonstrated the potential for the use of a 3D CNN for deep de-aliasing of real-time radial data, within the clinical setting. Clinical measures of ventricular volumes using real-time data with CNN reconstruction are not statistically significantly different from the gold-standard, cardiac gated, BH techniques

    HyperSLICE: HyperBand optimized spiral for low-latency interactive cardiac examination

    Get PDF
    PURPOSE: Interactive cardiac MRI is used for fast scan planning and MR-guided interventions. However, the requirement for real-time acquisition and near-real-time visualization constrains the achievable spatio-temporal resolution. This study aims to improve interactive imaging resolution through optimization of undersampled spiral sampling and leveraging of deep learning for low-latency reconstruction (deep artifact suppression). METHODS: A variable density spiral trajectory was parametrized and optimized via HyperBand to provide the best candidate trajectory for rapid deep artifact suppression. Training data consisted of 692 breath-held CINEs. The developed interactive sequence was tested in simulations and prospectively in 13 subjects (10 for image evaluation, 2 during catheterization, 1 during exercise). In the prospective study, the optimized framework-HyperSLICE- was compared with conventional Cartesian real-time and breath-hold CINE imaging in terms quantitative and qualitative image metrics. Statistical differences were tested using Friedman chi-squared tests with post hoc Nemenyi test (p < 0.05). RESULTS: In simulations the normalized RMS error, peak SNR, structural similarity, and Laplacian energy were all statistically significantly higher using optimized spiral compared to radial and uniform spiral sampling, particularly after scan plan changes (structural similarity: 0.71 vs. 0.45 and 0.43). Prospectively, HyperSLICE enabled a higher spatial and temporal resolution than conventional Cartesian real-time imaging. The pipeline was demonstrated in patients during catheter pull back, showing sufficiently fast reconstruction for interactive imaging. CONCLUSION: HyperSLICE enables high spatial and temporal resolution interactive imaging. Optimizing the spiral sampling enabled better overall image quality and superior handling of image transitions compared with radial and uniform spiral trajectories
    • …